Volt Control System's Single Phase Static Frequency Converters provide reliable frequency and voltage conversion for sensitive electrical equipment. Designed for precision, efficiency, and consistent performance, they ensure stable operation across various industrial and commercial applications.
| Product | Single Phase Static Frequency Converter | ||
|---|---|---|---|
| Capacity | 2-5 KVA | 6 - 7.5 KVA | 10 KVA |
| Input Voltage | 230VAC 1PH +/-10% | ||
| Input Frequency | 50Hz any factory configurable | ||
| Output Voltage | Any factory configurable | ||
| Output Frequency | 50Hz,60Hz,100Hz,400Hz,500Hz,1000Hz. Any factory configurable | ||
| Regulation | +/-1% | ||
| Waveform | Sinewave | ||
| Distortion | <3% on linear load <5% on non-linear load | ||
| Overload Protection | 110% for 1 minute and 150% for 1 second. | ||
| Ingress Protection | IP20 (Optional 2x,3x,4x,5x,6x) | ||
| Efficiency | >85% | ||
| Protections at Input | a) MCB | ||
| b) Over Voltage | |||
| c) Under Voltage | |||
| d) Surge Suppression | |||
| Protections at Output | a) Over Voltage | ||
| b) Under Voltage | |||
| c) Over Current | |||
| d) Short Circuit | |||
| e) Soft Start | |||
| Digital Meter | a) Input Voltage | ||
| b) Input Current | |||
| c) Input Frequency | |||
| d) Output Voltage | |||
| e) Output Current | |||
| f) Output Frequency | |||
| Enclosure Type | MS fabricated | ||
| Colour | RAL 7032 | ||
| Climatic conditions | |||
| Operating Temperature | -20 to + 55 degree C | ||
| Altitude | 3500 meter | ||
| Storage | -30 to + 70 degree C | ||
| Dimensions | 330x620x600 | 330x560x650 | 400x700x720 |
| Weight in KG | 45-60 | 70 | 80 |
| Standards Followed | ||||||
| IS5921/1249 | Copper cladbase material in electrical/electronic equipment's | |||||
| IS6297/2026 | Transformers and inductors. | |||||
| IS 6553 | Environmental requirements for semiconductors and Integrated circuits. | |||||
| IS4064 | Airbreak switches | |||||
| IS8828 | MCBs | |||||
| IS 9224 | HRC fuses | |||||
| IS1248 | Indicating instruments | |||||
| IS 6619 | Semiconductor Rectifier equipment safety | |||||
| IS613 | Copper busbars | |||||
| IS2959 | Contactors. | |||||
| IS3231 | Electrical relays | |||||
| IS13703 | Low voltage fuses | |||||
| IS4540 | Mono Crystal line Semi conductor rectifier assembly | |||||
| IS4237 | General requirements for switchgear and control switches | |||||
| IEC62040-2 | Electro magnetic conduction and interference. | |||||
* Due to VCS Policy of continuous improvement in product quality, some feature and Size of items may change.
Note: We also offer customized solutions tailored to specific customer requirements.