Our static voltage stabilizers provide rapid correction response and accurate output control to protect high-value equipment from power disturbances.
| Product | SINGLE PHASE STATIC VOLTAGE STABILIZER | ||
|---|---|---|---|
| CAPACITY | 2-5 KVA | 6 - 7.5 KVA | 10 KVA |
| INPUT VOLTAGE | 230VAC 1PH +/-10% | ||
| INPUT FREQUENCY | 50Hz ANY FACTORY CONFIGURABLE | ||
| OUTPUT VOLTAGE | ANY FACTORY CONFIGURABLE | ||
| OUTPUT FREQUENCY | ANY FACTORY CONFIGURABLE | ||
| REGULATION | +/-1% | ||
| WAVEFORM | Sinewave | ||
| DISTORTION | <3% On linear load <5% On non-linear load | ||
| OVERLOAD PROTECTION | 110% for 1 minute and 150% for 1 second. | ||
| INGRESS PROTECTION | IP20 (OPTIONAL 2x,3x,4x,5x,6x) | ||
| EFFICIENCY | >85% | ||
| PROTECTIONS AT INPUT | a) MCB | ||
| b) OVER VOLTAGE | |||
| c) UNDER VOLTAGE | |||
| d) SURGE SUPPRESSION | |||
| PROTECTIONS AT OUTPUT | a) OVER VOLTAGE | ||
| b) UNDER VOLTAGE | |||
| c) OVER CURRENT | |||
| d) SHORT CIRCUIT | |||
| e) SOFT START | |||
| DIGITAL METER | a) INPUT VOLTAGE | ||
| b) INPUT CURRENT | |||
| c) INPUT FREQUENCY | |||
| d) OUTPUT VOLTAGE | |||
| e) OUTPUT CURRENT | |||
| f) OUTPUT FREQUENCY | |||
| ENCLOSURE TYPE | MS FABRICATED | ||
| COLOUR | RAL 7032 | ||
| CLIMATIC CONDITIONS | |||
| OPERATING TEMPERATURE | -20 to +55 degree C | ||
| ALTITUDE | 3500 meter | ||
| STORAGE | -30 to +70 degree C | ||
| DIMENSIONS IN mm (APPROX) | 330x620x600 | 330x560x650 | 400x700x720 |
| WEIGHT IN KG (APPROX) | 45-60 | 70 - 100 | 100 - 120 |
| Product | Three Phase Static Voltage Stabilizer | |||||
|---|---|---|---|---|---|---|
| Capacity | 5 TO 20 KVA | 25 TO 50 KVA | 60 TO 80 KVA | 90 TO 125 KVA | 150 TO 200 KVA | 225 TO 300 KVA |
| Input Voltage | 415VAC 3PH +/-10% ANY FACTORY CONFIGURABLE | |||||
| Input Frequency | 50Hz ANY FACTORY CONFIGURABLE | |||||
| Output Voltage | ANY FACTORY CONFIGURABLE | |||||
| Output Frequency | ANY FACTORY CONFIGURABLE | |||||
| Regulation | +/-1% | |||||
| Waveform | Sinewave | |||||
| Distortion | <3% on linear load <5% on non linear load | |||||
| Overload Protection | 110% for 1 minute and 150% for 1 second. | |||||
| Ingress Protection | IP20 (OPTIONAL 2x,3x,4x,5x,6x) | |||||
| Efficiency | >85% | |||||
| Protections at Input | a) MCB OR MCCB | |||||
| b) OVER VOLTAGE | ||||||
| c) UNDER VOLTAGE | ||||||
| d) SURGE SUPPRESSION | ||||||
| Protections at Output | a) OVER VOLTAGE | |||||
| b) UNDER VOLTAGE | ||||||
| c) OVER CURRENT | ||||||
| d) SHORT CIRCUIT | ||||||
| e) SOFT START | ||||||
| Digital Meter | a) INPUT VOLTAGE | |||||
| b) INPUT CURRENT | ||||||
| c) INPUT FREQUENCY | ||||||
| d) OUTPUT VOLTAGE | ||||||
| e) OUTPUT CURRENT | ||||||
| f) OUTPUT FREQUENCY | ||||||
| Enclosure Type | MS FABRICATED | |||||
| Colour | RAL 7032 | |||||
| Climatic Conditions | CLIMATIC CONDITIONS | |||||
| Operating Temperature | -20 to +55 degree C | |||||
| Altitude | 3500 METER | |||||
| Storage | -30 to +70 degree C | |||||
| Dimensions in mm (Approx) | 800x600x800 | 800x600x1200 | 800x600x1800 | 1000 x 800 x 1900 | 1550 x 850 x 1800 | 1700x1000x2200 |
| Weight in kg (Approx) | 100 - 150 | 250 - 500 | 600 - 800 | 1000 - 1300 | 1300 - 1800 | 1800 - 2200 |
| Standards Followed | ||||||
| IS5921/1249 | Copper cladbase material in electrical/electronic equipment's | |||||
| IS6297/2026 | Transformers and inductors. | |||||
| IS 6553 | Environmental requirements for semiconductors and Integrated circuits. | |||||
| IS4064 | Airbreak switches | |||||
| IS8828 | MCBs | |||||
| IS 9224 | HRC fuses | |||||
| IS1248 | Indicating instruments | |||||
| IS 6619 | Semiconductor Rectifier equipment safety | |||||
| IS613 | Copper busbars | |||||
| IS2959 | Contactors. | |||||
| IS3231 | Electrical relays | |||||
| IS13703 | Low voltage fuses | |||||
| IS4540 | Mono Crystal line Semi conductor rectifier assembly | |||||
| IS4237 | General requirements for switchgear and control switches | |||||
| IEC62040-2 | Electro magnetic conduction and interference. | |||||